Antares Analytical offers a free Technical Bulletin for owners and users of Baird spectrometers. Our purpose is to help Baird users lower their operating costs and extend the life of their current equipment.

The bulletin, issue by issue, will cover the most common problems encountered, along with advice on maintenance and spotting potential problems. It will soon be available in Spanish as well as English.

If you or your company wish take advantage of this service please complete our short form and indicate how you would like to receive the bulletins. Please include any relevant information about you and your company. Register here please

If you have any comments, suggestions for future Technical Bulletins, questions about the topics or questions / problems about your Baird spectrometer please contact us at antaresanalytical@gmail.com


Bulletins available for online reading:

NEW  B19 - Communication errors on MC20 equipped Baird spectrometers: normal causes and the steps to take in pinpointing and resolving the problem.

B18 - Entrance optics solenoid, problems and solutions: background on use of solenoid systems, probable cause for problems, steps to take in resolving them.

B17 - The FSQ or DV2-5 Loss of Optical Alignment: possible causes, the underlying problems, the solutions.

B16 - The selection of Calibration and Standardization Standards for metallurgical, ICP and oil/fuel, their differences and advice on choosing and using CRMs and SUS.
B15 - Optical Cell Temperature Regulation. It affects the FSQ, DV6 and DV6E. Discussion of the temperature control system components, their settings and some typical problems and solutions.
B14 - No Burning in the MOA/FAS Sample Stand (part 2)
B13 - No Burn in the MOA/FAS Sample Stand. Troubleshooting and basic repair. (part 1) This also covers all MOA models, MOA-C, MOA-GT and MOA-M.
B12 - Argon Systems: Design and function of argon systems used in Baird spectrometers. This also covers argon powered sample clamps used in HR-400 equipped FSQ, DV5, DV6 and DV6E spectrometers. (part 2)
B11
- Argon Systems: Design and function of argon systems used in Baird spectrometers. This also covers argon powered sample clamps used in HR-400 equipped FSQ, DV-5, DV-6 and DV-6E spectrometers. (part 1)
B10 - Optical Components: General and specific information about the optical sysytems and components used in Baird spectrometers.
B9 - Vacuum System Maintenance, Troubleshooting and Repair (part 2)
B8
- Basic FSQ, DV, ICP Vacuum System Maintenance and Troubleshooting (part 1)
B7 - A Loss of PMT High Voltage in MC20 equipped FSQ or DV series.
B6
- Photomultiplier Tubes: General and specific information about the PMTs used in various Baird spectrometers.
B5
- Inaccurate Reference Result after a Routine Sample Analysis: The reference element gives a totally wrong value. The element values will also be totally wrong.
B4
- Loss of Optical Alignment Function: The spectrometer, all Baird models except ICP-2070, has no Hg (Mercury) alignment. Optical alignment on units with no Hg lamp.
B3
- Suspected Loss of High Voltage on the Baird rotrode model MOA. This bulletin does not cover the FAS
B2
- No Spark at the Sample Stand for the Baird arc spark units equiped with a KH-5 or HR400
B1 - Poor accuracy and precision for sulfur, phosporous and carbon on the Baird FSQ, DV4, DV5 and DV6

Sign up and receive your username and password to access these bulletins.